1、<p><b> ABSTRACT</b></p><p> With the development of modern society and economics , environmental issues are coming to our attention more and more . Pollution caused by domestic wastewater
2、 is getting worse and well noticed .Sewage treatment is becoming very important and indispensable .This paper is focused on the process design in our country for domestic wastewater treatment , and select the best proces
3、s scheme to make the treated water reach the quality that required .</p><p> This design have adopted the OD process and the procedure is simple ,management is convenient ,do not need to add the first sinki
4、ng pool , digestive system ,reducing building and operating expenses , realizing automation totally . At the same time , easy to manage ,making the water reach sewage discharge standard , accomplish the rational utilizat
5、ion of water resource.</p><p> KEY WORDS: Grid Pumping House OD The Second Sinking Pool Nitrogen and phosphor removal </p><p><b> 1緒論</b></p><p><b> 1.1課程設(shè)計(jì)
6、題目</b></p><p> 城市污水處理工藝設(shè)計(jì)</p><p><b> 1.2 設(shè)計(jì)依據(jù)</b></p><p><b> (1)污水水量</b></p><p> (a) 擬建污水處理規(guī)模是平均流量為40000 m3/d;</p><p> (
7、b) 城市污水主要包括居民生活污水和工業(yè)廢水;</p><p> (c) 城市混合污水變化系數(shù):總變化系數(shù) Kz=1.37。</p><p><b> (2) 進(jìn)水水質(zhì)</b></p><p> BOD5=170mg/L;TN=35mg/L; TP=3.8mg/L;總堿度=2000 mg/L。</p><p>&l
8、t;b> (3) 出水水質(zhì)</b></p><p> 城市污水經(jīng)處理后,就近排入廠區(qū)附近某河流。污水處理廠出水水質(zhì)根據(jù)GB18918-2002《城鎮(zhèn)污水處理廠污染物排放標(biāo)準(zhǔn)》的一級(jí)排放標(biāo)準(zhǔn)(B 標(biāo)準(zhǔn)),污水廠出水水質(zhì)控制為:</p><p> BOD5≦20mg/L; CODcr≦60mg/L; SS≦20mg/L;TN≦20mg/L; TP≦1.0mg/l。<
9、;/p><p><b> 1.3 處理程度</b></p><p> 污水處理程度是由對(duì)象和地區(qū)排放標(biāo)準(zhǔn)決定。</p><p> 1.3.1 進(jìn)出水水質(zhì)</p><p><b> 進(jìn)出水水質(zhì)見(jiàn)表1。</b></p><p><b> 表1 進(jìn)出水水質(zhì)<
10、/b></p><p><b> 1.3.2 去除率</b></p><p><b> 設(shè)去除率為E,則有</b></p><p> E= ×100%</p><p> 式中:——進(jìn)水物質(zhì)濃度;</p><p><b> ——出
11、水物質(zhì)濃度。</b></p><p> BOD5去除率:E= ×100%=88.24%</p><p> TN 去除率: E= ×100%=42.86%</p><p> TP 去除率:E= ×100%=60.53%</p><p> 2 城市污水處理方案
12、的確定</p><p> 2.1 確定污水處理方案的原則</p><p> (a)城市污水處理應(yīng)采用先進(jìn)的技術(shù)設(shè)備,要求經(jīng)濟(jì)合理,安全可靠,出水水質(zhì)好;保證良好的出水水質(zhì),效益高;</p><p> (b)污水廠的處理構(gòu)筑物要求布局合理,建設(shè)投資少,占地少;自動(dòng)化程度高,便于科學(xué)管理,力求達(dá)到節(jié)能和污水資源化,進(jìn)行回用水設(shè)計(jì);</p><p
13、> (c)為確保處理效果,采用成熟可靠的工藝流程和處理構(gòu)筑物;提高自動(dòng)化程度,為科學(xué)管理創(chuàng)造條件;</p><p> (d)污水處理采用生物處理,污泥脫水采用機(jī)械脫水并設(shè)事故干化廠;污水采用季節(jié)性消毒;</p><p> (e)提高管理水平,保證運(yùn)轉(zhuǎn)中最佳經(jīng)濟(jì)效果;充分利用沼氣資源,把沼氣作為燃料;</p><p> (f)查閱相關(guān)的資料確定其方案。&
14、lt;/p><p> 最佳的處理方案要體現(xiàn)以下優(yōu)點(diǎn):</p><p> (a)保證處理效果,運(yùn)行穩(wěn)定;</p><p> (b)基建投資省,耗能低,運(yùn)行費(fèi)用低;</p><p> (c)占地面積小,泥量少,管理方便。</p><p> 2.2 污水處理方法及工藝流程的的確定</p><p>
15、; 根據(jù)測(cè)量的水量、水質(zhì)和環(huán)境容量降低的結(jié)論確定污水及污泥處理應(yīng)達(dá)到的標(biāo)準(zhǔn),本節(jié)對(duì)其處理工藝流程進(jìn)行方案篩選,并通過(guò)論證選擇合理的污水及污泥處理工藝流程。</p><p> 2.2.1 污水處理方法的選擇</p><p> (1)物理法、化學(xué)法與生物處理方法。</p><p> 物理法主要是利用物理作用來(lái)分離或回收廢水中的懸浮物。它既可以用于廢水的預(yù)備處理,
16、也可用于一級(jí)處理,但在二級(jí)處理及三級(jí)處理或深度處理中,只是配合其他主要處理單元。</p><p> 化學(xué)法主要是利用化學(xué)反應(yīng)的作用來(lái)處理或回收廢水中的溶解物或膠體物,如酸堿中和、某些有用物質(zhì)的萃取、有害溶解氣體的吹脫等。化學(xué)法既可以單獨(dú)使用,也可以用于二級(jí)處理或三級(jí)處理(深度處理)。</p><p> 生物法是利用微生物的作用處理廢水的方法。有機(jī)物通過(guò)生物處理最后轉(zhuǎn)化為二氧化碳與無(wú)機(jī)鹽
17、類,但它不能回收廢水中的有用物質(zhì)。它可以用來(lái)進(jìn)行二級(jí)處理或三級(jí)處理(脫氮除磷)。</p><p> 以上各種方法都有它的特點(diǎn)和適用條件。一般來(lái)說(shuō),化學(xué)法往往消耗的物料(如藥劑)及能耗(燃料、電能)比其他兩類方法要大,有時(shí)大很多有時(shí)候污泥產(chǎn)生量也大,所以運(yùn)行費(fèi)用較貴。但是,處理設(shè)備較簡(jiǎn)單,占地面積較小,也可以連續(xù)運(yùn)行。有的廢水采用化學(xué)處理后能回收一些副產(chǎn)品,補(bǔ)償較高的支付費(fèi)用,其優(yōu)點(diǎn)就比較突出。</p>
18、;<p> 生物法處理廢水具有凈化能力強(qiáng),費(fèi)用低廉,支付可靠性好等優(yōu)點(diǎn),是廢水處理的主要的方法。對(duì)于某種污染物,若化學(xué)法與生物法都能凈化的話,一般選用生物法為宜。</p><p> (2)好氧生物處理法與厭氧生物處理法</p><p> 根據(jù)電子受體的性質(zhì),生物法可分為好氧和厭氧兩類(介于其間的為缺氧),這兩類又可分為固著生長(zhǎng)系統(tǒng)與懸浮生長(zhǎng)系統(tǒng)。廢水的好氧處理與厭氧處理
19、既可單獨(dú)使用,亦可組合使用,這取決于廢水的性質(zhì)、濃度及處理目標(biāo)。</p><p> 好氧生物處理法與厭氧生物處理法的特性比較列于表2。</p><p> 表2 好氧處理與厭氧處理的比較</p><p> 此外,在去除某些具體的污染物如磷則需要采用厭氧法。因此,根據(jù)本次課程設(shè)計(jì)的設(shè)計(jì)依據(jù)可知應(yīng)該選擇厭氧與好氧組合的方式。</p><p>
20、; 綜上所述,結(jié)合本設(shè)計(jì)的具體情況,我認(rèn)為采用傳統(tǒng)活性污泥法或?qū)鹘y(tǒng)活性污泥法進(jìn)行改造的人工生物凈化的技術(shù)路線是比較合適的、可行的。</p><p> 2.2.2污水處理工藝的選擇</p><p> 現(xiàn)階段城市污水處理應(yīng)用工藝較多,如表3所示。</p><p> 表3 幾種城市污水處理工藝的適用條件</p><p> 活性污泥法有
21、很多種形式,使用最廣泛的主要有三類: ①傳統(tǒng)活性污泥法和它的改進(jìn)型A/ O、/O工藝, ②氧化溝, ③SBR 工藝。從表3可以看出,第一種工藝適合于大中型污水處理廠,而氧化溝和SBR 工藝較為適合中小型污水廠采用。鑒于數(shù)量龐大的中小城市在城市污水水量、水質(zhì)和經(jīng)濟(jì)發(fā)展程度等方面具有共性,根據(jù)現(xiàn)有的中小城市處理經(jīng)驗(yàn),氧化溝工藝更適合被我國(guó)中小型污水處理廠采用。目前,我國(guó)對(duì)污水處理廠的規(guī)模按平均日流量劃分如表4。</p><
22、;p> 表4 污水處理廠規(guī)模劃分依據(jù)</p><p> 而本次設(shè)計(jì)處理污水的日平均流量為4萬(wàn)m3/d,屬于中型污水廠。另外,由于/O工藝處理單元多,操作管理復(fù)雜,特別是污泥厭氧消化要求高水平的管理,消化過(guò)程產(chǎn)生的沼氣是可燃易爆氣體,更要求安全操作,這些都增加了管理的難度。因此,本設(shè)計(jì)該選擇氧化溝工藝。其特點(diǎn)如下</p><p><b> (1)特點(diǎn):</b&g
23、t;</p><p> 氧化溝又名氧化渠或循環(huán)曝氣池,是1950 年由荷蘭公共工程研究所研究成功的。其本特征是曝氣池呈封閉的溝渠形。污水和活性污泥的混合液在其中不停地循環(huán)流動(dòng),其水力停留時(shí)間一般較長(zhǎng),為15~16h,泥齡長(zhǎng)達(dá)15~30d,屬于延時(shí)曝氣法。氧化溝處理系統(tǒng)的構(gòu)造形式較多,有圓形或馬蹄形的,有平行多渠道形式以側(cè)渠作為二沉池的,有將二沉池建在渠上或單獨(dú)分建的等等,其供氧和水流動(dòng)力都是靠提升曝氣設(shè)備,這種
24、設(shè)備分為早期使用的水平中心軸旋轉(zhuǎn)葉輪和后來(lái)出現(xiàn)的卡魯塞爾氧化溝所用的垂直或帶葉片的曝氣器,由于氧化溝水深較淺(一般3 米左右),而流程較長(zhǎng),可以按照曝氣器前作缺氧與曝氣器后作富氧段的方式設(shè)計(jì)運(yùn)行,提供兼氧菌與好氧菌交替作用的條件,在缺氧段脫硝,在好氧段除碳源需氧量及達(dá)到脫N 的目的。</p><p><b> (2)優(yōu)點(diǎn):</b></p><p> (a)氧化溝內(nèi)
25、循環(huán)流量很大,進(jìn)入溝內(nèi)的原污水立即被大量的循環(huán)水所混合和稀釋,因此具有很強(qiáng)的承受沖擊負(fù)荷的能力,對(duì)不易降解的有機(jī)物也有較好的處理效果。</p><p> (b)處理效果穩(wěn)定可靠,不僅可滿足BOD5、SS 的排放標(biāo)準(zhǔn),還可以達(dá)到脫N除P的效果。</p><p> (c)由于氧化溝的水力停留時(shí)間和泥齡都很長(zhǎng),懸浮物、有機(jī)物在溝內(nèi)可獲得較徹底的降解。</p><p>
26、 (d)活性污泥產(chǎn)量少且趨于穩(wěn)定,一般可不設(shè)初沉池和污泥消化池,有的甚至取消二沉池和污泥回流系統(tǒng),簡(jiǎn)化了處理流程,減少了處理構(gòu)筑物,使其基建費(fèi)用和運(yùn)行費(fèi)用都低于一般活性污泥法。</p><p> (e)承受水質(zhì)、水量、水溫能力強(qiáng),出水水質(zhì)好。</p><p> (3)缺點(diǎn):氧化溝運(yùn)行管理費(fèi)用較高;氧化溝溝體占地面積大。</p><p> 2.3 污水處理工藝
27、流程的確定</p><p> 由前面的論述可以得出本設(shè)計(jì)的工藝流程如圖1所示。</p><p> 污泥 污水</p><p> 圖1 污水處理工藝流程圖</p><p> 污水匯入集水井,經(jīng)粗格柵去除大顆粒及漂浮物,保護(hù)水泵的正常工作,進(jìn)入提升泵房,經(jīng)水泵提升后,由細(xì)格柵進(jìn)一步去除水中的雜質(zhì);污水在流經(jīng)沉砂
28、池去除泥沙,而后進(jìn)入?yún)捬踹x擇池池進(jìn)行厭氧釋磷,接著進(jìn)入氧化溝,在氧化溝內(nèi)完成生物氧化過(guò)程,達(dá)到分解有機(jī)物、去除水中N、P,使污水得到進(jìn)一步進(jìn)化。出水進(jìn)入二沉池,經(jīng)泥水分離后,上清液進(jìn)入接觸消毒池,消毒后出水達(dá)標(biāo)排放。當(dāng)TP指標(biāo)超標(biāo)時(shí),啟動(dòng)化學(xué)除磷設(shè)施,在氧化溝出水處加入無(wú)機(jī)混凝劑。該工藝不僅具有/O工藝組合進(jìn)氧化溝工藝,形成改良型/O型氧化溝,整個(gè)生物處理過(guò)程僅有二沉池回流污泥至厭氧調(diào)節(jié)池的回流系統(tǒng),因此該工藝不僅具有/O和氧化溝工藝的
29、特點(diǎn)和效能,且省去污泥回流系統(tǒng),故維護(hù)管理方便,運(yùn)行費(fèi)用低。剩余污泥由污泥泵提升至污泥脫水車間處理后外運(yùn)填埋。</p><p> 2.4 主要處理構(gòu)筑物的選擇</p><p><b> 2.4.1 格柵</b></p><p> 格柵由一組平行的金屬柵條或篩網(wǎng)組成,安裝在污水管道、泵房、集水井的進(jìn)口處或處理廠的端部,用以截留較大的懸浮物或
30、漂浮物,以便減輕后續(xù)處理構(gòu)筑物的處理負(fù)荷。格柵種類較多,如表5所示。</p><p> 表5 我國(guó)常用的機(jī)械格柵及其使用范圍</p><p> 綜合上表以及本次設(shè)計(jì)的條件,選擇鏈條式機(jī)械格柵作為粗格柵,移動(dòng)伸縮臂機(jī)械格柵作為細(xì)格柵,從而達(dá)到預(yù)處理的目的。</p><p> 2.4.2 污水泵房</p><p> 城市污水處理廠的運(yùn)行費(fèi)
31、用大部分來(lái)自于電能,其中40%的電能為水泵消耗,所以確定合理的水泵及泵站是污水處理廠的關(guān)鍵所在。泵站形式的選擇取決于水力條件和工程造價(jià),其它考慮因素還有:泵站規(guī)模大小、泵站的性質(zhì)、水文地質(zhì)條件、地形地物、挖渠及施工方案、管理水平、環(huán)境性質(zhì)要求、選用水泵的形式及能否就地取材等。目前污水泵站主要有以下幾種形式:</p><p> (a)合建式矩形泵站,裝設(shè)立式泵,自灌式工作臺(tái),水泵數(shù)為4 臺(tái)或更多時(shí),采用矩形,機(jī)器
32、間、機(jī)組管道和附屬設(shè)備布置方便,啟動(dòng)簡(jiǎn)單,占地面積大;</p><p> (b)合建式圓形泵站,裝設(shè)立式泵,自灌式工作臺(tái),水泵數(shù)不超過(guò)4 臺(tái),圓形結(jié)構(gòu)水力條件好,便于沉井施工法,可降低工程造價(jià),水泵啟動(dòng)方便。</p><p> (c)非自灌式泵房,泵軸高于集水池最高水位,不能直接啟動(dòng),由于污水泵水管不得設(shè)低閥,故需設(shè)引水設(shè)備。但管理人員必須能熟練的掌握水泵的啟動(dòng)程序。</p>
33、;<p> (d)潛水泵站,潛水泵的電機(jī)防水密封,可以長(zhǎng)期侵入污水中,不存在受潮問(wèn)題,潛水泵電機(jī)機(jī)組整體安裝,結(jié)構(gòu)緊湊,運(yùn)行穩(wěn)定,便于就位和更換,所以潛水泵站無(wú)需上部廠房,也簡(jiǎn)化了地下結(jié)構(gòu),降低了工程造價(jià)。但是潛水泵在水下運(yùn)行,所以要有可靠的產(chǎn)品質(zhì)量、自動(dòng)化控制和保護(hù)功能作技術(shù)依托,潛水泵價(jià)格較高。</p><p> 本設(shè)計(jì)因水量較小,并考慮到占地、造價(jià)、自動(dòng)化控制等因素,以及施工的方便與否,采
34、用潛污式矩形泵房。</p><p><b> 2.4.3 沉砂池</b></p><p> 沉砂池一般設(shè)于泵站倒虹吸管前,以便減輕無(wú)機(jī)顆粒對(duì)水泵、管道的磨損;也可設(shè)于初沉池前,以減輕沉淀池負(fù)荷及改善污泥處理構(gòu)筑物的處理?xiàng)l件。沉砂池的形式,按水流方向的不同可分為平流式、豎流式、曝氣沉砂池、旋流沉砂池四類。各沉砂池的特點(diǎn)如表6所示。</p><p&
35、gt; 表6 常用沉砂池及其特點(diǎn)</p><p> 基于以上四種沉砂池的比較,曝氣沉砂池除砂效果較好,且能耗較低;加之曝氣沉砂池有很強(qiáng)的除油能力,將有利于以后的氧化溝的表面曝氣和運(yùn)行穩(wěn)定,本工程設(shè)計(jì)確定采用曝氣沉砂池。</p><p><b> 2.4.4 氧化溝</b></p><p> 氧化溝技術(shù)發(fā)展加快,類型多樣。各種氧化溝的類
36、型及技術(shù)特點(diǎn)如表7:</p><p> 表7 幾種常見(jiàn)氧化溝的比較</p><p> 綜上所述,各種氧化溝各有優(yōu)缺點(diǎn),結(jié)合本設(shè)計(jì)用地較為緊張,以及基建費(fèi)用、運(yùn)行成本、運(yùn)行管理、處理要求等方面考慮,設(shè)計(jì)采用卡魯塞爾氧化溝 。</p><p><b> 2.4.5 二沉池</b></p><p> 由于本設(shè)計(jì)主要構(gòu)筑
37、物采用氧化溝,可不設(shè)初沉池,只設(shè)二沉池。 二沉池設(shè)在生物處理構(gòu)筑物的后面,用于沉淀去除活性污泥。沉淀池主要有以下幾種形式,如表8所示。</p><p> 表8 常用二沉池及其使用范圍</p><p> 綜上所述,四種沉淀池的優(yōu)缺點(diǎn)比較,并結(jié)合本設(shè)計(jì)的具體資料可知,本工程二沉池采用中心進(jìn)水、周邊出水的輻流式沉淀池。其結(jié)構(gòu)如圖2所示。</p><p> 圖2 輻
38、流式沉淀池結(jié)構(gòu)示意圖</p><p> 2.4.6 接觸消毒池</p><p> 接觸消毒池主要是使消毒劑與二沉池出水充分混合,殺死水中的細(xì)菌和病毒。對(duì)于消毒劑主要有如下幾種可供選擇,其優(yōu)缺點(diǎn)如表9所示。</p><p> 表 9 常用消毒劑及比較</p><p> 綜上三種消毒劑的比較,本工程設(shè)計(jì)采用常用且毒害作用較小的紫外線消毒
39、法。利用紫外燈管產(chǎn)生紫外線來(lái)殺滅病毒和細(xì)菌。 </p><p> 2.4.7 污泥濃縮池</p><p> 具有一定規(guī)模的污水處理工程中常用的污泥濃縮方法有主要有重力濃縮、氣浮濃縮和離心濃縮。這三種方法的特點(diǎn)如表10所示。</p><p> 表10 各種污泥濃縮方法的優(yōu)缺點(diǎn)</p><p> 重力濃縮池又可分為連續(xù)式重力濃縮池和間歇式
40、重力濃縮池兩種,由于本工藝設(shè)計(jì)水量較少,結(jié)合氧化溝工藝污泥穩(wěn)定,且污泥量較少,本設(shè)計(jì)采用間歇式重力濃縮池。</p><p> 2.4.8污泥脫水方法的選擇</p><p> 常用的污泥機(jī)械脫水方法有:板框壓濾、帶式壓濾、離心脫水和螺旋壓榨式脫水,其中帶式過(guò)濾脫水的方法的優(yōu)點(diǎn)是機(jī)器制造容易,附屬設(shè)備少,投資、能耗低,噪聲小;連續(xù)運(yùn)操作管理維修簡(jiǎn)便;濾帶可以回旋,脫水能力大。缺點(diǎn)是必須正確
41、選用有機(jī)高分子混凝劑,運(yùn)行費(fèi)用高;必須預(yù)先進(jìn)行充分的絮凝,形成大而強(qiáng)度高的凝絮,以便能加強(qiáng)過(guò)濾段的自由脫水,并能適應(yīng)進(jìn)一步逐漸加壓脫水;脫水效率較低,脫水后泥餅的含水率較高,大致與離心脫水相當(dāng)。它適用于無(wú)機(jī)性污泥的脫水,有機(jī)黏性污泥脫水不宜采用。四種脫水機(jī)械的能耗如表11所示。</p><p> 表11 脫水機(jī)的耗能比較</p><p> 根據(jù)以上比較,本設(shè)計(jì)采用帶式壓濾機(jī)。</
42、p><p> 3 城市污水處理系統(tǒng)的設(shè)計(jì)計(jì)算</p><p><b> 3.1 泵前粗格柵</b></p><p> 進(jìn)水粗格柵是污水處理廠第一道預(yù)處理設(shè)施,可去除大尺寸的漂浮物或懸浮物,以保護(hù)進(jìn)水泵的正常運(yùn)轉(zhuǎn),并盡量去掉那些不利于后續(xù)處理過(guò)程的雜物。其計(jì)算圖如圖3所示。</p><p><b> 圖 3
43、格柵計(jì)算圖</b></p><p> 3.1.1 設(shè)計(jì)原則</p><p> (a)格柵間隙一般采用10~40mm;</p><p> (b)格柵不宜少于兩臺(tái),如為一臺(tái)時(shí),應(yīng)設(shè)人工清除格柵備用;</p><p> (c)過(guò)柵流速一般采用0.4~0.9m/s;</p><p> (d)格柵傾角一般采
44、用45º~75º,機(jī)械格柵一般為60º~70º,特殊類型可達(dá)90º;</p><p> (e)通過(guò)格柵的水頭損失一般采用0.08 m/s~0.17m/s;</p><p> (f)格柵間必須設(shè)置工作臺(tái),臺(tái)面應(yīng)高出柵前最高設(shè)計(jì)水位 0.5m,工作臺(tái)有安全和沖洗設(shè)施;</p><p> (g)格柵間工作臺(tái)兩側(cè)過(guò)道寬
45、度不應(yīng)小于0.7m,工作臺(tái)正面過(guò)道寬度:人工清除,不小于1.2m;機(jī)械清除,不小于1.5m;</p><p> (h)機(jī)械格柵的動(dòng)力裝置一般宜設(shè)在室內(nèi)或采取其它保護(hù)設(shè)備的措施;</p><p> (i)設(shè)置格柵裝置的構(gòu)筑物必須考慮設(shè)有良好的檢修、柵渣的日常清除。</p><p> 3.1.2 設(shè)計(jì)參數(shù)</p><p><b>
46、 (1)日平均流量</b></p><p> =40000 /d≈1667 /h=0.463 /s=463L/s</p><p> 查生活污水流量系數(shù)變化表,由內(nèi)插法求得=1.37</p><p> (2) 最大設(shè)計(jì)流量</p><p> =· =1.37×0.463 /s =0.634 /s<
47、;/p><p> (3)柵條凈間隙為e=30mm,柵前流速=0.7m/s;</p><p> (4)過(guò)柵流速0.8m/s, 柵前部分長(zhǎng)度為0.5m;</p><p> (5)格柵傾角δ=60°</p><p> (6)單位柵渣量: =0.05 柵渣/ 污水。</p><p> 3.1.3 設(shè)計(jì)計(jì)算<
48、;/p><p><b> (1)確定柵前水深</b></p><p> 根據(jù)最優(yōu)水力斷面公式 計(jì)算得:</p><p> 所以柵前進(jìn)水渠寬約1.35m。柵前水深h≈0.68m</p><p><b> (2)柵條間隙數(shù)n</b></p><p> 式中:
49、 n—粗格柵間隙數(shù);</p><p> —最大設(shè)計(jì)流量, /s;</p><p> e—柵條間隙,取30mm;</p><p><b> h —柵前水深;</b></p><p> v —過(guò)柵流速,取0.8m/s;</p><p> α —格柵傾角,設(shè)計(jì)60°;</p&g
50、t;<p><b> (3)柵槽有效寬度</b></p><p> 柵槽寬度一般比格柵寬0.2—0.3m,在此取0.2m。本設(shè)計(jì)采用ø10圓鋼為柵條,S=0.01m。</p><p> 0.01×(37-1)+0.03×37+0.2=1.67m≈1.7m</p><p> 式中:B—柵槽有效寬
51、度,m;</p><p> S—柵條寬度,取0.01m</p><p> (4)進(jìn)水渠道漸寬部分的長(zhǎng)度:</p><p> 設(shè)漸寬部分展開(kāi)角 =20º,則進(jìn)水渠道漸寬部分長(zhǎng)度為:</p><p><b> 0.48m </b></p><p> (5)柵槽與出水渠道連接處的漸窄
52、部分長(zhǎng)度 :</p><p> = /2=0.48/2=0.24m</p><p> (6)通過(guò)格柵的水頭損失:</p><p><b> =K</b></p><p> 式中: —計(jì)算水頭損失; </p><p><b> g—重力加速度;</b></
53、p><p> K—格柵受污物堵塞使水頭損失增大的倍數(shù),一般取3;</p><p> ξ—阻力系數(shù),其數(shù)值與格柵柵條的斷面幾何形狀有關(guān),對(duì)于圓形斷面,</p><p><b> 則 </b></p><p> (7)柵后槽總高度H:</p><p> 設(shè)柵前渠道超高 =0.3m</p
54、><p> H=h+ + =0.68+0.3+0.035=1.015m</p><p> (8)柵槽總長(zhǎng)度L:</p><p> L= + +1.0+0.5+</p><p> 式中: —柵前渠道深 =h+ ,m</p><p> 則 L=0.48+0.24+1.0+0.5+
55、 =2.8m</p><p><b> (9)每日柵渣量W</b></p><p> 對(duì)于柵條間距b=30.0mm的中格柵,并對(duì)于城市污水,每單位體積污水?dāng)r截污物為 =0.05 柵渣/ 污水。則</p><p><b> 宜采用機(jī)械清渣</b></p><p><b> (10)
56、粗格柵選用</b></p><p> 根據(jù)格柵間距、寬度在《給水排水設(shè)計(jì)手冊(cè)》第9 冊(cè)上查得采用GH型鏈條式回轉(zhuǎn)格柵除污機(jī),其性能見(jiàn)表12。</p><p> 表 12 GH-1500型鏈條式回轉(zhuǎn)格柵性能規(guī)格表</p><p> 3.2 污水提升泵房</p><p><b> 3.2.1設(shè)計(jì)參數(shù)</b&g
57、t;</p><p> 設(shè)計(jì)流量:Q=634L/s,泵房結(jié)構(gòu)工程按遠(yuǎn)期流量設(shè)計(jì)。</p><p> 3.2.2 泵房設(shè)計(jì)計(jì)算</p><p> 采用氧化溝工藝方案,污水處理系統(tǒng)簡(jiǎn)單,對(duì)于新建污水廠,工藝管線可以充分優(yōu)化,故污水只考慮一次提升。污水經(jīng)提升后進(jìn)入集水井,然后自留通過(guò)旋流沉砂池、厭氧池、氧化溝、二沉池及接觸消毒池,最后由出水管道排入附近水體。<
58、/p><p> 根據(jù)設(shè)計(jì)流量Q=634L/s=2282 m3/h,采用3臺(tái)QW系列潛水排污泵,單臺(tái)提升流量761 /h。(由于本設(shè)計(jì)沒(méi)有涉及管道計(jì)算,故無(wú)法確定具體水泵的揚(yáng)程,在此只根據(jù)設(shè)計(jì)流量來(lái)選取水泵型號(hào))</p><p> 因此在《給水排水設(shè)計(jì)手冊(cè)》第11 冊(cè)上查得采用QW系列潛水排污泵(300QW800—15—55)4臺(tái),3用一備。其性能見(jiàn)表13。</p><
59、p> 表 13 QW 型潛水排污泵的規(guī)格性能表</p><p> 泵房占地面積為 S==3.14×=78.5,即為圓形泵房,其直徑D=10m,高12m,泵房為半地下式。地下埋深7m,水泵為自灌式。</p><p><b> 3.3集水池</b></p><p> 污水泵站的集水池宜采用敞開(kāi)式,本工程設(shè)計(jì)的集水池與泵房和
60、共建,屬封閉式。</p><p> (1)集水池容積計(jì)算</p><p> 泵站集水池容積一般按不小于最大一臺(tái)泵5 分鐘的出水量計(jì)算,有效水深取1.5—2.0 米。本設(shè)計(jì)集水池容積按最大一臺(tái)泵5分鐘的出水量計(jì)算,有效水深取1.8m。則</p><p> V= =66.67 取 V=80 </p><p> (2
61、)集水池面積計(jì)算:</p><p> 式中:—集水池的容積, </p><p> —有效水深,2.0m</p><p> 則 A=80/2.0=40</p><p> 根據(jù)《給排水設(shè)計(jì)規(guī)范》中的規(guī)定:集水池的長(zhǎng)寬比為2,可計(jì)算出該集水池的長(zhǎng)為9m,寬為4.5m, 則集水池有效容積尺寸為9×
62、4.5×2m。</p><p><b> 3.4 細(xì)格柵</b></p><p> 3.4.1 設(shè)計(jì)參數(shù)</p><p> (1)設(shè)計(jì)流量Q=4× m3/d=0.634 m3/d</p><p> (2)柵前水深h1=0.65m;</p><p> (3)過(guò)柵流速v
63、=0.9m/s,柵前流速 =0.7 m/s;</p><p> (4)柵條寬度s=0.01m,格柵間隙e=10mm;</p><p> (5)格柵安裝傾角θ=60º,柵前部分長(zhǎng)度為0.5m;</p><p> (6)單位柵渣量 =0.1柵渣/ m3污水。</p><p> 3.4.2 設(shè)計(jì)計(jì)算</p><
64、;p><b> (1)確定柵前水深</b></p><p> 根據(jù)最優(yōu)水力斷面公式 計(jì)算得:柵前槽寬 =1.35m,則柵前水深</p><p><b> (2)柵條間隙數(shù)n</b></p><p> = = 96.4(取n=100
65、)</p><p> 設(shè)計(jì)兩組格柵,每組格柵柵條間隙數(shù)為50</p><p><b> (3)柵槽有效寬度</b></p><p> 柵槽寬度一般比格柵寬0.2—0.3m,在此取0.2m。本設(shè)計(jì)采用ø10圓鋼為柵條,即S=0.01m。則</p><p> 0.01 (50 1)+0.01 50+0.2=
66、1.2m,考慮到中間隔墻厚0.2m</p><p> 所以總槽寬為1.2 2+0.2=2.6m。</p><p> (4)進(jìn)水渠道漸寬部分的長(zhǎng)度:</p><p> 設(shè)漸寬部分展開(kāi)角α1=20º,進(jìn)水渠道內(nèi)的流速為0.45m/s</p><p><b> =1.69m</b></p>&l
67、t;p> (5)柵槽與出水渠道連接處的漸窄部分長(zhǎng)度:</p><p> =/2=1.69/2=0.85m</p><p> (6)過(guò)柵水頭損失:</p><p><b> =K</b></p><p> 式中:h0—計(jì)算水頭損失; </p><p><b> g—
68、重力加速度;</b></p><p> K—格柵受污物堵塞使水頭損失增大的倍數(shù),一般取3;</p><p> ξ—阻力系數(shù),其數(shù)值與格柵柵條的斷面幾何形狀有關(guān),對(duì)于矩形斷面</p><p> 則 </p><p> (7)柵后槽總高度H:</p><p> 設(shè)柵前
69、渠道超高 =0.3m,則柵前總高度H1=h+ =0.68+0.3=0.98m,</p><p> 柵后槽總高度為: H=h+ + =0.68+0.3+0.26=1.24m</p><p> (8)柵槽總長(zhǎng)度L:</p><p> L= + +1.0+0.5+ =1.69+0.85+1.0+0.5+ </p><p><
70、b> =4.6m</b></p><p><b> (9)每日柵渣量</b></p><p><b> W=</b></p><p> =4.0 /d>0.2 /d</p><p> 宜采用機(jī)械格柵清渣。</p><p> (10)細(xì)格柵的
71、選用</p><p> 根據(jù)格柵間距、寬度在《給水排水設(shè)計(jì)手冊(cè)》第11 冊(cè)上查得采用XWB-Ⅲ系列背耙式格柵除污機(jī),其性能見(jiàn)表14。</p><p> 表 14 XWB-Ⅲ系列背耙式格柵除污機(jī)性能表</p><p><b> 3.5曝氣沉砂池</b></p><p> 3.5.1 設(shè)計(jì)原則</p>
72、<p> (1)旋流速度應(yīng)保持0.25~0.3m/s;</p><p> (2)水平流速為0.06~0.12 m/s;</p><p> (3)最大流量時(shí)停留時(shí)間為1~3min;</p><p> (4)有效水深為2~3m,寬深比一般采用1~2;</p><p> (5)長(zhǎng)寬比可達(dá)5,當(dāng)池長(zhǎng)比池寬大的多時(shí),應(yīng)考慮設(shè)置橫向
73、擋板;</p><p> (6)每立方米污水的曝氣量為0.1~0.2 m3空氣;</p><p> (7)空氣擴(kuò)散裝置設(shè)在池的一側(cè),距池底約0.6 ~0.9m,送氣管應(yīng)設(shè)置調(diào)節(jié)氣量的閘門;</p><p> (8)池子的形狀應(yīng)盡可能不產(chǎn)生偏流或死角,在集砂槽的附近可安裝縱向擋板;</p><p> (9)池子的進(jìn)口和出口布置,應(yīng)防止發(fā)
74、生短路,進(jìn)水方向應(yīng)與池中旋流方向一致,出水方向應(yīng)與進(jìn)水方向垂直,并應(yīng)考慮設(shè)置擋板;</p><p> (10)池內(nèi)應(yīng)考慮消泡裝置。</p><p> 3.5.2 設(shè)計(jì)參數(shù)</p><p> (1)本設(shè)計(jì)沉砂池采用一座,分兩格;</p><p> (2)最大設(shè)計(jì)流量=0.634 m3/s;</p><p> (
75、3)水力停留時(shí)間t取2min ;</p><p> (4)水平流速 取0.08m/s;</p><p> (5)有效水深 =2m。</p><p> 3.5.3 設(shè)計(jì)計(jì)算</p><p> (1) 沉砂池有效容積 </p><p> =0.634 2 60=76.1 m3</p><p&
76、gt;<b> (2)水流斷面面積</b></p><p><b> (3)池總寬度</b></p><p><b> (4)每格池寬度</b></p><p><b> 設(shè)n=2格</b></p><p><b> (5)池長(zhǎng)<
77、/b></p><p> (6)每小時(shí)所需空氣量</p><p> 設(shè)每立方米污水所需空氣量d=0.2 / ,則</p><p> (7)沉砂斗所需容積V</p><p> 取清除沉砂的間隔時(shí)間T=2d</p><p> 式中:X——為城市污水沉砂量,一般取0.03 /L(污水)</p>
78、<p> 每個(gè)沉砂斗容積 (V0),設(shè)每一分格有六個(gè)沉砂斗</p><p> (8)沉砂斗各部分尺寸計(jì)算</p><p> (a)沉砂斗上口寬a</p><p> 取沉砂斗斗高,斗底寬a1=0.5m,斗壁與水平面的傾角為55o</p><p><b> (b)沉砂斗容積</b></p>
79、<p> V0 = 0.2 </p><p><b> (9)沉砂室高度</b></p><p> 采用重力排砂,池底坡度為0.06,坡向砂斗</p><p> 式中 為兩砂斗之間寬度,取0.2m。</p><p><b> (10)池總高度</b></p>
80、<p> 設(shè)超高h(yuǎn)1=0.3m</p><p> H=h1+ + =0.3+2+0.57=2.87m</p><p><b> 3.6 厭氧池</b></p><p> 為使氧化溝具有除磷脫氮的功能,在氧化溝之前設(shè)生物選擇器及厭氧池,這樣,污水可以在這里進(jìn)行厭氧中重要的釋磷作用以及部分反硝化作用。</p><
81、;p> 3.6.1 設(shè)計(jì)參數(shù)</p><p> 考慮到厭氧池與氧化溝為一個(gè)處理單元,總的水力停留時(shí)間超過(guò)15h,所以設(shè)計(jì)水量按最大日平均時(shí)考慮。</p><p> (1)污水日平均流量 =463.0 L/s,分四座厭氧池,每座設(shè)計(jì)流量為Q=115.8 L/s;</p><p> (2)水力停留時(shí)間t=2.5h;</p><p>
82、 (3)污泥濃度:X=3000mg/L</p><p> (4)污泥回流液濃度: =10000mg/L</p><p> 3.6.2 厭氧池的設(shè)計(jì)計(jì)算</p><p><b> (1)厭氧池容積</b></p><p><b> V=Q·t</b></p><
83、p> 式中:V—厭氧池容積, m3</p><p> t—水力停留時(shí)間,s</p><p> 則 V=115.8× 2.5 3600=1042m3</p><p><b> (2)厭氧池尺寸</b></p><p> 取有效水深為 h=4.0m</p>
84、<p><b> 則厭氧池表面積:</b></p><p> = 261</p><p><b> 厭氧池直徑:</b></p><p> D= 18.2m (取D=19m)</p><p> 考慮到0.3m的超高,故池總
85、高為</p><p> H=h+0.3=4+0.3=4.3m</p><p> (3)污泥回流量計(jì)算</p><p><b> 污泥回流比為</b></p><p><b> R=</b></p><p><b> 污泥回流量為</b><
86、/p><p> =RQ=0.43 115.8=49.79 L/s=4302 m3/d</p><p> 3.7 氧化溝工藝設(shè)計(jì)</p><p> 3.7.1 設(shè)計(jì)參數(shù)</p><p> 擬采用卡魯塞爾式氧化溝,除去除BO 和COD之外,還具備硝化和一定的脫氮除磷作用,使出水 -N低于排放標(biāo)準(zhǔn)。設(shè)計(jì)參數(shù)如下</p><p
87、> (1)污水量:Q=40000 /d;</p><p> (2)總污泥齡:30d;</p><p> (3)MLSS=3600mg/L, MLSS/MLVSS=0.75,則MLVSS=2700;</p><p> (4)污泥產(chǎn)率系數(shù)Y=0.55;</p><p> (5)進(jìn)水TKN=25 mg/L, -N =10 mg/L;
88、</p><p> (6)出水TN=20mg/L, -N = 8mg/L;</p><p> (7)堿度SALK=2000 mg/L (以CaCO3 計(jì));</p><p> (8)最低水溫T=10 ;</p><p> (9) 濃度=170mg/L, =20 mg/L;</p><p> (10)內(nèi)源呼吸系
89、數(shù)Kd=0.055;</p><p> (11)20 時(shí)脫氮率qdn=0.035</p><p><b> 3.7.2設(shè)計(jì)計(jì)算</b></p><p><b> (1) 去除計(jì)算</b></p><p> (a)氧化溝出水溶解性濃度 為了保證沉淀池出水濃度,必須控制氧化溝出水所含溶解性濃度
90、,因?yàn)槌恋沓爻鏊械腣SS也是構(gòu)成濃度的一個(gè)組成部分。</p><p><b> = -1.42 </b></p><p> =20-1.42 0.7 20 =6.4 mg/L</p><p> (b) 好氧區(qū)容積 </p><p> (c)好氧區(qū)的水力停留時(shí)間t1</p><p>
91、(d) 剩余干污泥量△X</p><p> 去除每1kg產(chǎn)生的干污泥量為:</p><p> 剩余總污泥量(按含水率99%計(jì))</p><p><b> =</b></p><p> (2)校核總磷的去除量</p><p> 剩余污泥中含有總磷量= =3438.2 0.05=171.9k
92、g/d</p><p> 設(shè)計(jì)要求去除的總磷量=(3.8-1.0)×40000×1.37 /1000=153.4 kg/d</p><p> 因此,只用氧化溝就可以使出水中總磷的含量達(dá)到排放要求,不再需要化學(xué)除磷。</p><p><b> (3)脫氮量計(jì)算</b></p><p> (a)需
93、氧化的氨氮量 </p><p> 氧化溝產(chǎn)生的剩余污泥中含氮率為12.4%,則用于生物合成的總氮量為:</p><p> 需要氧化的氨氮量 =進(jìn)水 - 出水 -N - 生物合成所需氮量 ,即:</p><p> =35-8-4.21=22.8mg/L</p><p> (b)脫氮量Nr=進(jìn)水總氮量-出水總氮量-生物合成所需的氮量<
94、;/p><p> Nr=35-20-4.21=10.8 mg/L</p><p><b> (c)堿度平衡</b></p><p> 每氧化1mg -N 需消耗7.14mg/L 堿度;每氧化1mg/LBOD5產(chǎn)生0.1mg/L 堿度;每還原1mg —N 產(chǎn)生3.75mg/L 堿度</p><p> 則剩余堿度=原水堿
95、度-硝化消耗堿度+反硝化產(chǎn)生堿度+氧化BOD5 產(chǎn)生堿度</p><p> =2000-7.14 22.8+3.75 10.8+0.1 (170-6.41=1894.1mg/L</p><p> (d) 脫氮所需要的容積 </p><p><b> 脫氮率 :</b></p><p> 考慮最不利的條件水溫,最低
96、水溫為10 </p><p><b> 時(shí) </b></p><p><b> 脫氮所用容積</b></p><p><b> 停留時(shí)間</b></p><p> (4)氧化溝總?cè)莘e及停留時(shí)間t</p><p> 校核污泥負(fù)荷
97、 </p><p> 設(shè)計(jì)規(guī)程規(guī)定氧化溝污泥負(fù)荷應(yīng)為0.05~0.1kgBOD5/(kgMLVSS.d),因此滿足要求。</p><p><b> (5)需氧量計(jì)算</b></p><p> (a)設(shè)計(jì)需氧量AOR</p><p> AOR=去除 需氧量-剩余污泥中 的需氧量+去除 -N耗氧量-剩余污泥中 -N
98、的耗氧量-脫氮產(chǎn)氧量</p><p> ?、?去除BOD需氧量 </p><p> 式中:d—微生物對(duì)有機(jī)底物氧化分解的需氧率,取0.52;</p><p> b‵—活性污泥自身氧化需氧率,取0.12;</p><p> 則 =0.52×40000 (0.17-0.0064)+0.12×25091
99、×2.7</p><p> =11532.4kg/d</p><p> ?、?剩余污泥中BOD的需氧量D2(用于生物合成的那部分BOD需氧量)</p><p> ?、?去除NH3-N需氧量D3</p><p> 每1kg NH3-N 硝化需要消耗4.6kg </p><p> ④ 剩余污泥中NH3-N耗
100、氧量D4</p><p> =4.6污泥含氮率剩余污泥量</p><p><b> ?、?脫氮產(chǎn)氧率 </b></p><p> 每還原1kgN2 產(chǎn)生2.86kgO2</p><p> =2.86×脫氮量 =2.86×10.8×40000/1000=1235.5kg/d</p&
101、gt;<p><b> 總需氧量</b></p><p> =11532.4-4882.2+4968-1961.1-1235.5</p><p> =8466.6kg/d</p><p> 考慮安全系數(shù)1.2,則AOR=1.2×8466.6=10159.9kg/d</p><p> 校核
102、去除每1kg 的需氧量</p><p> (b)標(biāo)準(zhǔn)狀態(tài)下需氧量SOR</p><p> 式中:——20 時(shí)氧的飽和度 取9.17mg/L </p><p> ——25 時(shí)氧的飽和度 取8.38mg/L</p><p> C ——溶解氧的濃度 取2mg/L</p><p> ——修正系數(shù),取0.85<
103、/p><p> ——修正系數(shù),取0.95</p><p> T ——進(jìn)水最高溫度, </p><p> SOR=16353.1kg /d</p><p> 校核去除每1kgBOD的標(biāo)準(zhǔn)需氧量=</p><p> (6) 氧化溝的尺寸計(jì)算</p><p> (a)設(shè)計(jì)氧化溝4座,分為2組,
104、則每座氧化溝容積為 ,即</p><p> (b)設(shè)計(jì)氧化溝有效水深h=5m,超高為1m,氧化溝深度H=5+1=6m,中間分隔墻厚度為0.25m,則氧化溝的面積為</p><p> (c)設(shè)計(jì)單溝道寬度b=7m</p><p><b> 彎道部分的面積</b></p><p> = =159.4+324.4=4
105、83.8 </p><p><b> 直線部分面積</b></p><p> =A- =1254.6-483.8=770.8 </p><p><b> 單溝直線段長(zhǎng)度</b></p><p> (7)進(jìn)水管和出水管計(jì)算</p><p> 污泥回流比R=43%<
106、;/p><p><b> 進(jìn)出水管流量</b></p><p> 進(jìn)出水管控制流速V=1.0m/s</p><p><b> 則管道過(guò)水?dāng)嗝?lt;/b></p><p> 管徑,取0.5m,即500mm</p><p> 校核管道流速,滿足要求。</p>&l
107、t;p> (8)出水堰以及出水豎井計(jì)算</p><p> 為了能夠調(diào)節(jié)氧化溝的運(yùn)行及出水,氧化溝出水處設(shè)置出水豎井,豎井內(nèi)安裝電動(dòng)可調(diào)節(jié)堰。初步估計(jì)δ/H<0.67,因此按照薄壁堰來(lái)計(jì)算 </p><p><b> (a)出水堰 </b></p><p><b> 式中:b—堰寬;</b></
108、p><p> H—堰上水頭高取0.2m。</p><p><b> =1.02m</b></p><p> 為了便于設(shè)備選型 b取1.0m,校核堰上水頭H</p><p><b> (b) 出水豎井</b></p><p> 考慮可調(diào)堰安裝要求堰兩邊各留0.3m的操作
109、距離</p><p> 出水豎井長(zhǎng) L=0.32+b=0.6+1.0=1.6m</p><p> 出水豎井寬B取1.4m(考慮安裝要求)</p><p> 則:出水豎井平面尺寸為L(zhǎng)B=1.6m1.4m</p><p> 氧化溝出水孔尺寸為bh=1.0m0.5m</p><p> (9)曝氣設(shè)備選擇 </
110、p><p><b> 單座氧化溝需氧量 </b></p><p> 每座氧化溝設(shè)2臺(tái)卡魯塞爾專用倒傘形葉輪表面曝氣機(jī), 單臺(tái)曝氣機(jī)所需充氧能力為170.3/2=85.2kgO2 /h。</p><p><b> 3.8 堰式配水井</b></p><p> 3.8.1 設(shè)計(jì)參數(shù)</p>
111、;<p> (1)污水量Q=40000 /d;</p><p><b> (2)=1.37;</b></p><p> (3)回流污泥量 =4302 /d;</p><p> (4)氧化溝出水經(jīng)配水井至四座二沉池</p><p> 3.8.2 設(shè)計(jì)計(jì)算</p><p>&l
112、t;b> (1)進(jìn)水管管徑</b></p><p> 配水井進(jìn)水管的設(shè)計(jì)流量為</p><p> 當(dāng)進(jìn)水管管徑 =1200mm時(shí)</p><p><b> 滿足設(shè)計(jì)要求 </b></p><p> (2) 頂堰設(shè)計(jì)計(jì)算</p><p> 混合液從配水井底中心進(jìn)入
113、,經(jīng)相等寬度的4 個(gè)堰口流入4 個(gè)水斗,再由管道接入4 座輻流式沉淀池。每個(gè)沉淀池的分配水量為q=2462.6/4=615.7 /h =0.17 /s,采用矩形寬頂溢流堰。 </p><p><b> (a)堰上水頭H</b></p><p> 設(shè)計(jì)擬采用堰高H=0.4m</p><p> 矩形堰的流量 </p
114、><p> 式中:q——矩形堰的流量,m3/s</p><p><b> H——堰上水頭,m</b></p><p> b——堰寬,m,取0.6m</p><p> m——流量系數(shù),通常采用0.327-0.332,在此取0.33 </p><p><b> 則 </
115、b></p><p> 基本與設(shè)計(jì)擬定堰高相等,則符合要求</p><p><b> (b)堰頂厚度B</b></p><p> 根據(jù)有關(guān)試驗(yàn)資料,當(dāng)2.5<B/H<10 時(shí),屬于矩形寬頂堰,取B=1.5m。這時(shí)B/H=4.4(在2.5-10 之間)所以該堰屬于矩形寬頂堰。</p><p> (
116、c) 配水管管徑D </p><p> 二沉池設(shè)計(jì)進(jìn)水管徑為500mm,則流速為 </p><p> 符合流速 0.6-0.9m/s 要求</p><p> (d) 配水漏斗上口口徑</p><p> 按配水井內(nèi)徑的1.5倍設(shè)計(jì)</p><p>
117、; =1.5D=1.5×1200=1800mm </p><p><b> 3.9 二沉池</b></p><p> 3.9.1 設(shè)計(jì)原則</p><p> (1) 沉淀池個(gè)數(shù)或分格數(shù)不應(yīng)少于兩個(gè),并宜按并聯(lián)系列設(shè)計(jì);</p><p> (2) 沉淀池的直徑一般不小于10m,當(dāng)直徑小于20m時(shí),可采
118、用多斗排泥;當(dāng)直徑大于20m時(shí),應(yīng)采用機(jī)械排泥;</p><p> (3) 沉淀池有效水深不大于4m,池子直徑與有效水深比值不小于6;.</p><p> (4) 池子超高至少應(yīng)采用0.3m;</p><p> (5) 為了使布水均勻,進(jìn)水管四周設(shè)穿孔擋板,穿孔率為10%—20%。出水堰應(yīng)用鋸齒三角堰,堰前設(shè)擋板,攔截浮渣。</p><p&
119、gt; (6) 池底坡度不小于0.05;</p><p> (7) 用機(jī)械刮泥機(jī)時(shí),生活污水沉淀池的緩沖層上緣高出刮板0.3m,工業(yè)廢水沉淀池的緩沖層高度可參照選用,或根據(jù)產(chǎn)泥情況適當(dāng)改變其高度。</p><p> (8) 當(dāng)采用機(jī)械排泥時(shí),刮泥機(jī)由絎架及傳動(dòng)裝置組成。當(dāng)池徑小于20m時(shí)用中心傳動(dòng),當(dāng)池徑大于20m時(shí)用周邊傳動(dòng),轉(zhuǎn)速為1.0—1.5m/min(周邊線速),將污泥推入污
120、泥斗,然后用靜水壓力或污泥泵排除;作為二沉池時(shí),沉淀的活性污泥含水率高達(dá)99%以上,不可能被刮板刮除,可選用靜水壓力排泥。</p><p> (9) 進(jìn)水管有壓力時(shí)應(yīng)設(shè)置配水井,進(jìn)水管應(yīng)由井壁接入不宜由井底接入,且應(yīng)將進(jìn)水管的進(jìn)口彎頭朝向井底。</p><p> 3.9.2 設(shè)計(jì)參數(shù)</p><p> (1) 表面負(fù)荷取0.8—2m3/m2.h,沉淀效率40%
121、—60%;</p><p> (2) 池子直徑一般大于10m,有效水深大于3m; </p><p> (3) 池底坡度一般采用0.05;</p><p> (4) 進(jìn)水處設(shè)閘門調(diào)解流量,進(jìn)水中心管流速大于0.4m/s,進(jìn)水采用中心管淹沒(méi)或潛孔進(jìn)水,過(guò)孔流速為0.1—0.4m/s,潛孔外側(cè)設(shè)穿孔擋板或穩(wěn)流罩,保證水流平穩(wěn);出水處應(yīng)設(shè)置浮渣擋板,擋渣板高出池水面0
122、.15—0.2m,排渣管直徑大于0.2m,出水周邊采用鋸齒三角堰,匯入集水渠,渠內(nèi)流速為0.2—0.4m/s;</p><p> (5) 排泥管設(shè)于池底,管徑大于200mm,管內(nèi)流速大于0.4m/s,排泥靜水壓力1.2—2.0m,排泥時(shí)間大于10min。</p><p><b> 3.9.3設(shè)計(jì)計(jì)算</b></p><p><b>
123、; (1)主要尺寸計(jì)算</b></p><p><b> (a)池表面積:</b></p><p><b> A=</b></p><p> 式中:A—池表面積,m2;</p><p> —最大設(shè)計(jì)流量,m3/h ;</p><p> q—水力表面負(fù)
124、荷,本設(shè)計(jì)1.5 m3/·h</p><p> 則 A= =1522.2</p><p><b> ?。╞)單池面積:</b></p><p> 本次設(shè)計(jì)設(shè)4座輻流式沉淀池。</p><p><b> 380.6</b><
125、;/p><p><b> (c)池直徑:</b></p><p><b> 本設(shè)計(jì)取D=23m</b></p><p> (d)沉淀部分有效水深:</p><p> 式中:t——沉淀時(shí)間,本設(shè)計(jì)取t=2.0h</p><p> =1.5×2.0=3.0m&l
126、t;/p><p> (e)污泥區(qū)的容積V</p><p> 設(shè)計(jì)采用周邊傳動(dòng)的刮吸泥機(jī)排泥,污泥區(qū)容積按2h 貯泥時(shí)間確定</p><p><b> 設(shè)計(jì)4 個(gè)二沉池</b></p><p> 每個(gè)沉淀池污泥區(qū)的容積</p><p> = =2462/4=615.4 m3</p>
溫馨提示
- 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 眾賞文庫(kù)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 水處理課程設(shè)計(jì)-- 城市污水處理工藝設(shè)計(jì)
- 水處理課程設(shè)計(jì)---生活污水處理工藝設(shè)計(jì)
- 污水處理工藝設(shè)計(jì)課程設(shè)計(jì)
- 水污染課程設(shè)計(jì)---城市污水處理工藝設(shè)計(jì)
- 城市污水處理課程設(shè)計(jì)
- 污水處理廠課程設(shè)計(jì)--生活污水處理站工藝設(shè)計(jì)
- 污水處理-課程設(shè)計(jì)
- 污水處理課程設(shè)計(jì)
- 污水處理課程設(shè)計(jì)
- 污水處理課程設(shè)計(jì)
- 某縣城市污水處理工程課程設(shè)計(jì)
- 水處理課程設(shè)計(jì)---污水處理廠
- 污水處理課程設(shè)計(jì)--污水處理氧化溝工藝的初步設(shè)計(jì)
- 畢業(yè)設(shè)計(jì)---污水處理廠污水處理工藝設(shè)計(jì)
- 課程設(shè)計(jì)--城市污水處理廠設(shè)計(jì)
- 城市污水處理廠課程設(shè)計(jì)
- 城市污水處理廠課程設(shè)計(jì)
- 水處理課程設(shè)計(jì)--某城市污水處理廠初步設(shè)計(jì)
- 城鎮(zhèn)污水處理課程設(shè)計(jì)
- 淺談城市污水處理工藝
評(píng)論
0/150
提交評(píng)論